THE BASIC PRINCIPLES OF ATS SOCOMEC

The Basic Principles Of ATS Socomec

The Basic Principles Of ATS Socomec

Blog Article

Safety and reliability ATyS p have each electrical and mechanical interlocks for maximum security. The 0 position provides electrical protection disconnection and will allow TSE lockout According to IEC60947-3.

Strong, dependable and superior executing Rated for crisis methods and overall method devoid of derating, these switches also contain significant brief-circuit score with unique breakers or fuses around a hundred kA.

Far more strong The current style involves metallic mounting legs across the whole ATyS selection, improving upon the overall robustness from the switches.

Good Grid, storage for integrating renewable Electrical power and islanding, a established reality Solenbat optimises the Energetic Power performance of buildings Stem, Electricity storage techniques for reduced electrical power billing Paradise, a smart network with the local community Innovation Near

=> Bộ ATS sẽ có chức năng sử dụng tự đồng và cả chức năng sử dụng bằng tay

Versatile space conserving The ATyS C35 controller may be mounted on possibly a DIN rail or towards the panel doorway, providing overall flexibility and optimising Area.

Speedy commissioning ATyS g switches offer sizeable time conserving throughout commissioning (system normally takes two to 3 minutes). Owing to the look that enables commissioning through just 4 potentiometers and 4 DIP switches, a screwdriver is all of that is necessary to configure the parameters.

For more protection, a tripping operate is available, allowing for gonna 0 position without the need of external ability provide in the event of 2 resources blackoutand a long term position monitoring and also communication attribute.

ATyS C65 is a sophisticated ATSE controller providing all the features from the ATyS C55 with the addition of latest, electrical power & energy checking, elevated I/O ability and functions, load shedding, elevate Manage perform, Power backup, amplified quantity of situations and alarms (measurement and mixture alarms) and DIRIS Digiware module compatibility.

Simplified maintenance Maintenance may be carried out very easily beneath load, with guide operation even now readily available.

Integrated auxiliary contacts As Portion of the product or service checking function, the ATyS g allow the transmission of knowledge regarding their posture. This is possible thanks to the normal integration of an auxiliary Get hold of for every posture.

BLUE GALAXY GROUP là tổ chức giáo dục được thành lập từ năm 2009 chuyên cung cấp các chương trình học

Probability to established periodic genset startup Chance to established periodic genset startup ATyS p switches give more features for maintenance. They include a programmable genset setting up purpose which makes it possible for the commencing dates click here and operating situations to get configured.

ATyS C25 be certain the automated or remotely controlled transfer from one resource to another with set timers and thresholds.

Versatile House conserving The ATyS C25 controller is usually mounted on either a DIN rail or on the panel doorway, supplying overall flexibility and optimising House.